Create a calibrator from the range map's plane to
create an intrinsic and extrinsic calibration based on the AQS12
calibrationPiece.
Namespace: Stemmer.Cvb.Foundation
Assembly: Stemmer.Cvb.Foundation (in Stemmer.Cvb.Foundation.dll) Version: 14.0.0.0
Syntax
public static Calibrator3D CalibratorFromPiece( ImagePlane plane, Rect aoi, AQS12Piece calibrationPiece, out Point3Dd[] residuals )
Parameters
- plane
- Type: Stemmer.CvbImagePlane
Range map's image plane showing an AQS12 calibration piece. - aoi
- Type: Stemmer.CvbRect
The area of interest to use within the given plane. - calibrationPiece
- Type: Stemmer.Cvb.FoundationAQS12Piece
Reference points describing the calibration piece. - residuals
- Type: Stemmer.CvbPoint3Dd
Newly created array containing the residuals to check on the create calibration.
Return Value
Type: Calibrator3DNewly created calibrator object.
Remarks
See Also